This information must be validated by university architects and planners prior to submission. If external funding entities require matching fund commitments, a department preparing a grant proposal should work with its Vice Chancellor. Departments developing proposals to secure funds for facility improvements or new construction should follow these steps:. Email Capital Planning at capitalplanning ucsd. Toggle navigation. RMP Home.

Build your skills — from workshops and career programs to management development and online training. UCLA dedicates a number of services and resources to helping you maintain a healthy work-life balance. Come to work on a beautiful campus in Westwood, one of the most pleasant neighborhoods in Los Angeles, a mere five miles from the Pacific Ocean. Great public and campus transportation systems serve the needs of our workforce. Enjoy the restaurants, shops and theaters that make up Westwood Village and the surrounding area.

As an employer, UCLA offers an incredible benefits package: comprehensive medical coverage, generous retirement options, paid holidays and vacation, and other programs that promote both your professional growth and personal well-being.

Home About. Roll down fire doors. Automatic extinguishing systems FM, dry chemical extinguishers, etc. Additional work required by code or local jurisdiction. System Description and Function: 1. The system shall consist of power supplies, interface with remote fire alarm panel, on campus, remotely mounted building annunciator panel s , automatic detection devices, manual reporting stations, speakers with ADA strobes, and all wiring.

The entire system shall be equipped with an emergency battery back-up system. The system shall be fully field programmable. The system shall be capable of operating both addressable and non-addressable devices.

Fire alarm system wiring shall be Class B. The system shall function as follows under an alarm condition: i. Sound the audio alarm and cause visual signals to flash on all floors of the building. Automatically notify the Campus Police Station with one of the signals specified in Paragraph 2. Display individual addressable device number on Liquid Crystal Display LCD annunciator in the fire alarm control panel with University's Representative defined message. Contractor shall request any necessary clarification prior to initiating any programming on the system.

Device Abbreviations - Examples of University-defined messages are shown below: 1. DUC - Duct detector 2.

HD - Heat detector 3. M - Manual station 4. PRS - Low air pressure typical for pre-action system 5. TAM - Tamper switch 6. TBL - Trouble 7. SD - Smoke detector integral with door closer 8. SMK - Smoke detector 9. WF - Water flow BD - Beam smoke detector H. Close all magnetically held fire doors in the building.

Unlock security doors. Perform all functions in the Sequence of Operations shown on the drawings. In the event of any conflict between the Sequence of Operations and requirements in the specification, Contractor shall obtain clarification from the University's Representative prior to performing the work in question.

The system shall function as follows when any area elevator detector operates: 1. Close associated elevator accordion door on the activated floor only. Activate elevator return sequence on the associated elevator bank. Activation of any fire sprinkler valve tamper switch shall cause a supervisory signal at the fire alarm control panel, the remote annunciator, and a common trouble at the Campus Trouble Desk.